Search UK public tenders and contract notices

Official notices, one row per procedure. Filters use published facts only: delivery region from the notice, buyer type from the official classification, route and agreement type as published, never a Tenderline score.

Syntax:"exact phrase"cleaning OR cateringsoftware -consultancy(cleaning OR catering) AND hospitalgovern*admin+defenceocds-…

More filters
How
What
WhoA buyer type and a specific contracting authority are alternatives: choosing one clears the other.
When & money
Reset

Planned

Showing 1–3 · planned procurement and market-engagement notices for the coming year: expected date ahead or published in the last 12 months.

  1. Planned · expected · not yet publishedBelow threshold - open competition

    1" Cryogenic Vacuum Insulated Control Valve

    Health and Safety Executive · Central government · Nationwide (UK)

    HSE require a 1" cryogenic control valve for an experimental programme. The valve must be suitable for liquid hydrogen service (down to 20 K) and have continuous analog control between 0 - 100% open. The valve should be controlled electrica…

    • Piping
    • Industrial process control equipment
    Value
    £22k
    Term
    7 months
    Submit via
    portal not identified
    Published
    #05ff19
  2. Planned · expected · not yet publishedBelow threshold - open competition

    3" Cryogenic Valve

    Health and Safety Executive · Central government · Nationwide (UK)

    HSE require a 3" cryogenic valve for an experimental programme. The valve must be suitable for liquid hydrogen service (down to 20 K) and have pneumatic actuation (open/closed). The valve should have a position indicator rated for ATEX Zone…

    • Piping
    • Industrial process control equipment
    Value
    £18k
    Term
    7 months
    Submit via
    portal not identified
    Published
    #05ff18
  3. Planned · expected · not yet publishedBelow threshold - open competition

    3" Cryogenic Hydrogen Vent Stack with Changeable Terminations

    Health and Safety Executive · Central government · Nationwide (UK)

    HSE require a 3" vent stack for use with cryogenic hydrogen for an experimental programme. The vent must have interchangeable terminations (miter cut, bullhorn) which may be on a flanged connection or otherwise joined. The vent stack (inclu…

    • Piping
    • Industrial process control equipment
    Value
    £25k
    Term
    7 months
    Submit via
    portal not identified
    Published
    #05ff17